Vertiv Liebert Online UPS 10000VA/9000W GXT-MTPLUS CX

MODEL GXT-`10000MTPLUS CX230
CAPACITY 10000 VA / 9000 W
Power Factor 0.9
Transfer Time - Bypass to Inverter (Line mode) Zero
Inverter to Bypass (Line mode) Pure Signwave
Battery Type 12V x 9 AH
Numbers 16
Charging Current (max.) 1A / 2A
LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
Dimension, D x W x H (mm) 442×190×688
Net Weight 66KG
Brand: VERTIV
Warranty: 1 YEAR WARRANTY
Availability: In Stock
Rs. 698,000
MODEL GXT-10000MTPLUS CX230
CAPACITY                     10000 VA / 9000 W 

Input                           
Nominal Voltage           208/220/230/240VAC

Input Voltage Range    110-300 VAC (Based on load at 50%); 176-300 VAC (Based on load at 100%)
Frequency Range         46~54 Hz or 56~64 Hz
Power Factor                ≥ 0.99 @ Nominal Voltage (100% load)

OUTPUT                     
Output Voltage               208/220/230/240VAC
Voltage Regulation        ± 1%
Frequency Range (Synchronized Range)  46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode)                  50 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio                                      3:1
Harmonic Distortion                                    ≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-linear Load)

Transfer Time
Bypass to Inverter (Line mode)                 Zero
Inverter to Bypass                                       Zero
Waveform (Battery Mode)                        Pure Signwave

Waveform (Batt. Mode)
AC Mode                           93%
Battery Mode                    91%              

BATTERY
Battery Type                     12V/ 9 AH
Numbers                           16
Typical Recharge Time   9 hours recover to 90% capacity
Charging Current (max.) 1.0A / 2.0A
Charging Voltage             218.4 VDC±1%

INDICATORS
LCD Panel                        UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

ALARM
Battery Mode                 Sounding every 4 seconds
Low Battery                    Sounding every second
Overload                        Sounding twice every second
Fault                               Continuously sounding 

PHYSICAL
Dimension,                    D x W x H (mm) 442×190×688
Net Weight (kg)            66

ENVIRONMENT
Humidity                       0-95% RH @ 0-40°C (non-condensing)
Noise Level                  Less than 58dBA @ 1 Meter

MANAGEMENT
Smart RS-232/USB       Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC.
Optional SNMP             Power management from SNMP manager and web browser
No Specifications Found